Palladium Tank Plating Kit – 1 Litre

You can purchase this kit as it is or if you wish, you can use it as a guide to put together your own bespoke kit. Click on the items in the list to see detailed product information.

£1,792.48 + VAT

Microplater Classic × 2

£143.69 + VAT each

Standard Red Lead - 800mm 

800mm

Standard Red Lead - 600mm 

600mm

Standard Black Lead × 2 - 600mm 

600mm

Palladium Tank Plating Solution - 1 Litre 

1 Litre

Palladium Tank Replenisher - 50ml 

50ml

Palladium pH Adjuster (For UK and EU only) - 250ml 

250ml

pH 7 Buffer - 250ml 

250ml

Pipettes - Small 

Small

Pipettes - Medium 

Medium

Medline MS300 Hotplate Stirrer

£194.13 + VAT

Cleaner - 1 Litre 

1 Litre

MPU - 100ml 

100ml

Crocodile Clip (long-life) × 3

£3.26 + VAT each

Gold Plated Test Strip × 2

£2.26 + VAT each

Stirring Bar - Large 

Large

Plating Beaker - 1 Litre 

1 Litre

Beaker Ring for Plating in a Beaker - 1 Litre 

1 Litre

Platinum Rod Electrode for Beaker Plating × 4 - For 1 Litre Beaker 6mm Diameter 

For 1 litre Beaker, L=124mm, D=6mm

Anode Bag × 4 - 1 Litre 

1 Litre

Rinse Beaker - 1 Litre 

1 Litre

Stainless Mesh Electrode (For Cleaning Only) - 1 Litre 

1 Litre

Beaker Lid × 2 - 1 Litre 

1 Litre

Temperature Probe

£22.22 + VAT

Plating Timer

£18.28 + VAT

Plating Stand

£46.85 + VAT

Plating Arm and Boss × 2

£77.53 + VAT each

Gold Plated Jigging Wire

£3.23 + VAT

Wire Cutters

£4.69 + VAT

Plastic Tweezers

£1.77 + VAT

Rinse Bottle

£8.31 + VAT

In stock

Rinse Beaker × 2 - 500ml 

500ml

Safety Glasses

£4.69 + VAT

Assorted Nitrile Gloves

£1.19 + VAT

Share

SKU: 4552-1-1 Categories: ,

Our Palladium Tank Plating Kit – 1 Litre is a great option for re-plating white gold jewellery. The price of the kit includes 1 Litre of our Palladium Tank Plating Solution. This contains 6 grams of palladium per litre and we can ship it outside the UK and EU. Because of this it a good substitute for our transport restricted rhodium and platinum plating processes.

Scaling up or down; you can scale the volume of your kit up or down by swapping in different volumes of our plating beakers. You can also switch easily between our different plating solutions, as the Spa Plating tank plating process is very similar across all of our tanks plating solutions.

If you want to scale down the volume of the 1 litre kit to a 500ml kit for example, these are the core items you will need to change;

Palladium Tank Plating Kit – 500ml

Palladium Tank Plating Solution – 500ml

Cleaner – 500ml

Stainless mesh electrode – 500ml

Stirring Bar – Medium

Plating Beaker – 500ml

Mesh electrode – 500ml

Beaker Lid – 500ml x 2

Rinse beakers x 6 – 500ml

These same core products can be scaled down further to 250ml or up to 2 litres.

The rest of the items on the kit list can stay.

 

Our Palladium Tank Plating Solution deposits a bright white, hard-wearing layer of palladium. It is an excellent alternative to rhodium for re-plating white gold wedding and engagement rings.

You can safely palladium plate items of jewellery that include materials such as pearl or coral without having to mask them out. This is because our Palladium Tank Plating Solution will not etch materials made from calcium carbonate.

In between uses of your palladium tank plating solution, it’s a good idea to cover it with cling film to stop particles of dust and hair getting in. Keeping it dust free will lengthen the life of your solution.

Back to Product Description

How to set up the Microplater Classic

You can use the Microplater Classic for pen, brush and beaker/tank electroplating
It is particularly useful for tank plating as you can programme it.
You can also monitor the amount of electricity you are using (in amp hours) and this, when used with our online calculators, helps you plate to specific thicknesses.
The default settings do not need to be changed but can be viewed. This is talked about below.

Overview

The Microplater Classic is an electroplating rectifier which outputs dc voltage within the range 0.6 – 30 volts and amps between 0.00 and 3.5

You can set the volts and amps (along with other parameters) using the dial. To control the output, use the yellow on/off switch.

The black negative output and three red positive outputs allow for the three different processes of pen, brush and tank plating to be run from the Microplater.

There is plenty of venting on the sides and base of the unit.

Switching on

To power up the unit, plug in the power lead from the adapter or 9 volt battery into the socket on the back of the unit and press the green button. This will light up when the power is on.

Please note that we only recommend using the battery option with pen plating, not with brush or tank.

The Microplater can be powered with a lead (1) or with a battery (2).

How to switch the Microplater Classic to pen and brush plating mode

1. Make sure the output indicator (1) displays ‘OFF’ by depressing the yellow Output On/Off switch (3).

Take a note of the correct voltage for your pen or brush plating solution – it is displayed on the side of your plating solution bottle.

2. To set the voltage, briefly depress the dial (2). The last digit in the output indicator will start flashing. You can now adjust this digit up or down by turning the dial clockwise (up) or anticlockwise (down).

To move to the next decimal place, depress the dial again and while this digit is flashing you can adjust this one, by turning the dial.

Continue to the next digit to complete the voltage setting.

3. Select the amps by pressing and holding down the dial until the last digit of the amps starts flashing. As above, adjust the amps by rotating the dial clockwise and anticlockwise. To set all the decimal places of the amps, follow the same procedure you followed for the volts.

4. For both pen and brush plating mode, adjust the amps to 3.5 Please note that 3.5 amps is very unlikely to be reached during the plating process and only indicates a maximum value.
The volts figure, however, should remain unchanged from its set value during the plating process.

6. When you’re ready to start plating, press the output ON/OFF button so that it says ‘On’ in the output indicator.

Please note that you can program the output to be permanently on in Program Mode which is discussed below.

How to switch the Microplater Classic to beaker/tank plating mode

Tank plating is different to pen or brush plating in that the important setting is the amps rather than the volts. To work out the correct amp setting for your piece of work and the tank plating solution you’re using you will need to use one of our online plating calculators. Links to these can be found under ‘Calculators’ on our main menu. Once you have established the correct amp setting, take a note of this.

1. Make sure the output indicator (1) displays ‘OFF’ by depressing the yellow Output On/Off switch (3).

2. First set the volts to 5. This will be the same for every subsequent tank plating job you carry out and is the standard volt setting for tank plating. Follow the same procedure for selecting the correct volts as that outlined above for pen and brush plating.

3. Now you will need to enter in the amp setting you have worked out with one of our online calculators. Select the amps by pressing and holding down the dial (2) until the last digit of the amps starts flashing. As above, adjust the amps by rotating the dial clockwise (up) and anticlockwise (down). The amps figure should remain unchanged during the beaker/tank plating process.

4. Lower your work into the plating solution and press the yellow ON/OFF button to start plating.

Palladium Tank Calculator

Amp and Time Settings

pH Control

For technical specifications on any component of the electroplating kit, please visit its product page an click on the ‘Tech Specs’ tab.

General guide;

Certain small items, for example Swabs, Nibs and Plating Pens can be sent by normal post within the UK

  • The courier option for UK deliveries is FedEx
  • Free UK mainland delivery available on orders over £200
  • International orders usually 3-5 working days.

For all price quotations for deliveries, please add your items to our shopping cart. You will be able to see the shipping costs by clicking on the ‘Calculate shipping’ button in the cart and before checking out.

You can access our MSDS by scanning the QR code which is on our product bottles.
Here is a video to show you how;