Fault
|
|
Possible cause
|
|
Corrective action
|
1. No plating at all.
|
|
a) Electricity not flowing: Multiplater. |
|
Check that the green dot is showing on the MultiPlater. If the dial shows ‘Standby’, then you need to put it into plating mode where a green light should show on the dial. If a red light shows, then it indicates a broken plating circuit (see next) |
| b) Bad connection in the plating circuit. |
Check all electrical connections including the connection between the crocodile clip and Beaker Ring, Platinum Rod Anode and Beaker Ring and connections into the MultiPlater. |
c) Reverse polarity usually indicated in discoloured or
etched workpiece |
Check that the black lead is plugged into the black socket on the MultiPlater and the other end to the workpiece. Check also that the red lead is plugged into the red socket on the MultiPlater and the other end to the Beaker Ring. |
| d) Contamination with nickel, chromium, zinc or iron. |
Replace solution. |
| e) Platinum Rod Electrodes have become passive (highly unlikely) |
No platinum remaining on electrode. The only way this can practicably happen is that the electrode has been mechanically abraided removing the platinum coating. In this case, the electrode will need to be replaced or sent to us for re-platinum plating. |
2. Dullness of plate in the middle of articles and recesses.
|
|
a) Amp setting too low |
|
Check the surface area of the workpiece and recalculate the current (amps). |
|
b) Lack of brighteners |
|
Add 0.5ml of CopperPro Brightener for every litre of solution and check for difference. If there’s little or no difference, add another 0.5ml of CopperPro Brightener per litre together with 0.5ml of CopperPro Glossing Agent. |
|
c) CopperPro Brightener and Glossing Agent out of balance. |
|
Dummy plate out on a scrap workpiece for 10,000 coulombs making the recommended additions of CopperPro Brightener but not adding CopperPro Glossing Agent. Then add 0.5ml of CopperPro Glossing Agent and continue plating making additions as per the CopperPro Calculator. |
|
c) Temperature too high. |
|
Reduce temperature to within operating range (see Tech Specs) |
| d) Low conductivity. |
The bath starts off at a lower conductivity. The conductivity will increase as the bath is used (using our Platinum Rod Electrodes) and brightness distribution will also increase. Plate out on a scrap workpiece to obtain higher conductivity keeping up with all replenishers as per CopperPro Calculator. |
| e) Copper content too high. |
Lower the copper content by allowing to plate out without making Copper Electroforming Replenisher additions. |
3. Deposit dull all over.
|
|
a) Organic contamination |
|
Treat with Carbon Powder (see shop). Add 10ml of Copper Electroforming Brightener for every litre of solution treated. Run the plating bath until full brightness resumes. |
4. Burnt deposit especially on corners and edges. Nodular in extreme cases.
|
|
a) Amp setting too high. |
|
Decrease the amp setting. |
| b) Article too close to the anode. |
Move the item in the beaker or rearrange the anodes. |
|
c) Low copper content evident in clearness of solution. |
|
Add Copper Electroforming Replenisher at 40 grams for every litre. Repeat until original solution colour has returned. |
| d) Too little agitation. |
Increase agitation. |
| e) Temperature too low. |
Increase temperature. Please note that deposit will become less bright if the temperature is raised over 25 centigrade. |
5. Matt deposit, rough in extreme cases.
|
|
a) Particulate contamination especially in small installations without continuous filtration. |
|
Filter solution into a clean beaker/container. |
6. Pitting of deposit – small holes which can become larger on further plating.
|
|
a) Air bubbles originating from bare rod electrodes |
|
Fit anode bags. |
| b) Particulate matter in solution. |
Filter. |
| c) Grease or oil contamination in solution. |
Treat with Carbon Powder as above. |
7. Unplated area (step or skip plating).
|
|
a) Improper cleaning |
|
Check cleaning cycle especially for water breaks (see Online Manual) |
8. Unplated areas especially in tight recesses.
|
|
a) Air bubbles sticking to workpiece. Air bubbles can escape from the top of anode bags due to the level of solution being too high.
b) Air bubbles can also form if mechanical stirring action is too high causing a vortex.
c) Caused by air agitation.
d) Air can also be introduced via continual filtration especially if the filter is blocked and or the filter is dragging air in due to unsecured connection(s). |
|
Check the level of solution is below the top of the anode bag.
Turn the stirring action down on your hotplate stirrer/stirrer.
Consider switching to a mechanically agitated system (stirrer or hotplate stirrer).
Reduce the rate of filtration and/or change the inline filter. Ensure all connections are secure. |
9. Vertical tide marks especially evident on thin, flat articles.
|
|
a) Laminar nature of agitation especially when stirring. |
|
Consider using a stirrer with reversing action in order to make the agitation more turbulent. |
10. Streaking of deposit.
|
|
a) Excessive brightener additions. |
|
Plate out without adding brightener. |
| b) Organic contamination. |
Treat with Carbon Powder as above. |
| c) Contaminated rises or lack of rinsing. |
Extend rinsing cycle. |
11. Deposit peels from basis metal.
|
|
a) Improper cleaning. |
|
Check the cleaning cycle for the metal (see Online Manual). |
| b) Check the type of metal being plated. |
Consider gold flash intermediate coating especially of plating on brass, steel or stainless steel (refer to Online Manual for a list of pre-treatment stages). |