Korad 5 Amp Rectifier

£102.74 + VAT

Out of stock

Share

SKU: 17986 Category:

We recommend this power supply for use as a rectifier for brush and beaker plating where higher current (amps) are used. It’s one of the most easily programmable power supplies on the market and features an amp readout accurate to 0.001 A (1 milliamp) which is important when plating small items such as rings and findings. Easy-to-read display LED display, responsive dials, if purchased from us, one-year replacement guarantee.

Here is the rectifier set up for pen plating. Please click on the Videos tab for a demonstration on how to set up this rectifier for pen plating.
Please note:

  • When set up for pen plating, the CV light should be illuminated when in operation.
  • Please note the photo opposite is not the Korat rectifier and is for illustration
    only.

Here is the rectifier set up for brush plating. Please click on the Videos tab for a demonstration on how to set up this rectifier for brush plating.
Please note:

  • When set up for pen and brush plating, the CV light should be illuminated when in operation.
  • Please note the photo opposite is not the Korat rectifier and is for illustration
    only.

Here is the rectifier set up for tank plating. Please click on the Videos tab for a demonstration on how to set up this rectifier for tank plating.
Please note:

  • When set up for tank plating, the CC light should be illuminated when in operation.
  • Please note the photo opposite is not the Korat rectifier and is for illustration
    only.

Please click on the Videos tab of the Tenma 3A rectifier for modes of operation.

Tenma 3 Amp Rectifier

Back to Product Description

Operating Conditions and Deposit Data

Voltage Range / Current Range 0 – 30V / 0 – 5A
Load Regulation Voltage : ≤0.01% +2mV / Current : ≤0.1% +5mA
Line Regulation Voltage : ≤0.01% +3mV / Current : ≤0.1% +3mA
Setup Resolution Voltage : 10mV / Current : 1mA
Setup Accuracy (25°C ±5°C) Voltage : ≤0.5% +20mV / Current : ≤0.5% +5mA
Ripple (20Hz – 20MHz) Voltage : ≤1mVrms / Current : ≤3mArms
Temp. Coefficient Voltage : ≤100ppm +10mV / Current : ≤100ppm +5mA
Read Back Accuracy Voltage : 10mV / Current : 1mA
Read Back Temp. Coefficient Voltage : ≤100ppm +10mV / Current : ≤100ppm +5mA
Reaction Time (10% Rated load) Voltage : ≤100mS / Current : ≤100mS
Operation Environment Indoor use
Altitude : ≤ 2,000m
Ambient temperature : 0ºC to 40°C
Relative humidity : ≤ 80%
Weight and Dimension 4kg / 110mm(W) × 156mm(H) × 260mm(D)
Storage Environment Ambient temperature : -10ºC to +70ºC
Relative humidity : ≤ 70%

Notes:

  • For videos showing modes of operation, please view information under Videos tab.
  • When set up for pen and brush plating, the CV light should be illuminated when in operation.
  • When set up for tank plating, the CC light should be illuminated when in operation.

General guide;

Certain small items, for example Swabs, Nibs and Plating Pens can be sent by normal post within the UK

  • The courier option for UK deliveries is FedEx
  • Free UK mainland delivery available on orders over £200
  • International orders usually 3-5 working days.

For all price quotations for deliveries, please add your items to our shopping cart. You will be able to see the shipping costs by clicking on the ‘Calculate shipping’ button in the cart and before checking out.